As Favorite   |   As homepage   |   中文版  
 
 
 
 
 
 
 
 
 
Organic heat carrier boiler:
Coal organic heat carrier furnace
Coal organic heat carrier furnace
Coal organic heat carrier furnace
Fuel organic heat carrier furnace
Fuel organic heat carrier furnace
Wood organic heat carrier furnace
Electric organic heat carrier furnace
Wood heat carrier furnace
Integrated organic heat carrier furnace
Heat engineering
SZL series of coal-fired hot water boiler steam
WNS series gas-fired boiler fuel
Bulk coal-fired hot water boiler
Steam generator
Burner:
Imported supporting burner
Water coal slurry burner
The most advanced combustion system in China
The most advanced and economical technology flow of the first one in China
 
       
WNS series gas-fired boiler fuel
Model
WNS1-1.0-Y(Q)
WNS2-1.0-Y(Q)
WNS4-1.25-Y(Q)
WNS6-1.25-Y(Q)
WNS8-1.25-Y(Q)
WNS10-1.25-Y(Q)
Evaporation rated(t/h)
1
2
4
6
8
10
Rated working pressure(Mpa)
1
1
1.25
1.25
1.25
1.25
Rated steam temperature(℃)
184
184
193
193
193
193
Water temperature℃
20
20
20
104
104
104
Body water volume(m3
2.1
3
7.1
10.2
11.8
14.6
Boiler efficiency(%)
>90
>90
>90
>90
>90
>90
The application of fuel
Light oil, heavy oil, natural gas, liquefied petroleum gas, city gas
Fuel consumption
Light oil(kg/h)
69
138
272
376
504
628
Heavy oil(kg/h)
74
147
289
399
536
667
Natural gas(Nm3/h)
79
158
312
431
578
720
LPG(Nm3/h)
26
55
109
150
201
251
City Gas(Nm3/h)
180
362
712
983
1319
1643
Dimensions
length A(mm)
4200
5100
6022
7151
7600
8360
width B(mm)
2450
2500
2700
2800
3000
3000
High H(mm)
2234
2380
2684
2882
3200
3200
Boiler weight(t)
4.9
7.3
12.6
17.2
18.6
23.5
Import and Export caliber(mm)
50
65
100
125
150
150
Safety valve diameter(mm)
40×2
40×2
50×2
65×2
65×2
80×2
Chimney diameter(mm)
350
400
500
600
700
700
Model
WNS0.7-0.7/95/70-Y(Q)
WNS1.4-0.7/95/70-Y(Q)
WNS2.8-0.7/95/70-Y(Q)
WNS4.2-0.7/95/70-Y(Q)
WNS5.6-0.7/95/70-Y(Q)
WNS7-0.7/95/70-Y(Q)
Rated thermal power(MW)
0.7
1.4
2.8
4.2
5.6
7
Rated water pressure
(MPa)
0.7
0.7
0.7
0.7
1
1
Rated outlet water temperature
(℃)
95
95
95
95
95
95
Rated temperature of imports
(℃)
70
70
70
70
70
70
Water cycle(m3/h)
24
48
96
144
193
241
Body water volume(m3
2.1
4.2
7.1
9.8
11.5
13.8
Boiler efficiency(%)
>90
>90
>90
>90
>90
>90
The application of fuel
Light oil, heavy oil, natural gas, liquefied petroleum gas, city gas
Fuel consumption
Light oil(kg/h)
66
130
256
373
498
621
Heavy oil(kg/h)
70
139
272
396
529
660
Natural gas(Nm3/h)
75
149
293
427
571
711
LPG(Nm3/h)
26
52
102
149
199
248
City Gas
(Nm3/h)
171
341
670
976
1303
1632
Dimensions
length A(mm)
4100
5038
6100
6800
7600
8160
width B(mm)
2300
2280
2600
2800
3000
3000
High H(mm)
3200
2240
2700
2900
3110
3110
Boiler weight(t)
4.9
7.2
12.3
15.1
19.1
20.7
Import and Export caliber(mm)
65
100
150
200
200
200
Safety valve diameter(mm)
50
100
50×2
65×2
65×2
80×2
Chimney diameter(mm)
350
400
500
600
700
700
 
 
 
 
     
 

WEBSITE © JNJRL Jieneng Heating Furnace
Address: Liulv Road, Hudai Industrial Park, Binhu District, Wuxi City TEL:0510-85583388
FAX:0510-85582333 Website:http://www.jnjrl.com E-Mail:jnjrl@hotmail.com PC:214161